Information Name: | Roads and tunnels intelligent lighting control system |
Published: | 2013-07-16 |
Validity: | 999 |
Specifications: | |
Quantity: | 5000.00 |
Price Description: | |
Detailed Product Description: | Highland Technology Co., Ltd. of Shenzhen City Tour http://www.syblusea.com roads and tunnels intelligent lighting control system System Overview? Intelligent lighting control system is composed of field data bus, a distributed control network lighting management systems. All parts are built-in processor, each component has an address online, via the bus all the components of a control network. ? Intelligent lighting control system by the control unit, the execution unit, monitor components and network components and other components. Control means includes a control panel, touch screen, detector, controller, intelligent clock editor, the user; execution unit with dimming module, a switch module; network element containing communication cable, gateways. Green intelligent building system features? Intelligent lighting control system diversification. ? Intelligent lighting control system module size as the standard modulus. ? Fully decentralized modular structure, each component can work independently of any one component damage will not affect the operation of other components. ? With fire linkage. ? With system equipment monitoring functionality, ease of maintenance operations department. First, the terminal controller terminal controller SYS-RTU-ST01 adjustable duty cycle of the PWM output signal to control LED brightness, brightness switching process is fade (gradual change); supports single-lamp control, dual-lamp control, three lights control, four light control; product meets safety certification, CE certification; has a waterproof and dustproof function; support standard rail mounting. Hardware components: STM32 microcontroller, power supply module, PWM circuit module, AD converter circuit, DA converter circuit, CAN circuit, RS232/RS485 circuit, digital input circuits, relay control circuit functions and features? Input voltage DC12V-DC24V? Working power ≤ 2W? 6 Road 10V PWM dimming signal? controls the bus: CAN bus? Dimensions 121MM * 131MM * 56MM? digital inputs: Integrated 2-channel digital input? Analog input: Integrating an analog input? Analog Output: Integrated an analog output? Operating temperature / humidity: -40 ℃ ~ +70 ℃ / 0-95% RH? loop control functions: Integrated two-way switch output? Isolation Voltage: 2500V? channel AD converter power? RS232/RS485 Interface? local upgrade: through the serial port on the terminal controller software upgrade two, repeater relay SYS-RL-ST01 Each CAN repeater can connect up to 100 branch CAN devices, if more than this number or the distance is too long, need to add a repeater. Division I is not just a simple repeater signal amplifier also includes addressing and routing capabilities, can be composed of multi-level tree network structure, network free-form. Hardware components: STM32 microcontroller, power supply module, PWM circuit module, AD converter circuit, DA converter circuit, CAN circuit, RS232/RS485 circuit, digital input circuits, relay control circuit. Functions and features? Input voltage DC12V-DC24V? Working power ≤ 2W? Controls the bus: CAN bus? Dimensions 121MM * 131MM * 56MM? Operating temperature / humidity: -40 ℃ ~ +70 ℃ / 0-95% RH? Relay function : automatic forwarding data concentrator function, can effectively extend the communication distance and terminal controller number? Isolation voltage: 2500V? RS232/RS485 interfaces? local upgrade: through the serial port for software upgrades three repeaters, centralized controller centralized controller SYS-CC-ST01 high performance ARM9 processor, embedded Linux operating system, you can store instructions and data; communication failure with the monitoring center can be run independently, automate tasks plan, the completion of an administrative node controller and control; upward compatible GRPS / CDMA, TCP / IP, RS232, RS485 multi-protocol communication with the monitoring center; downward compatible with CAN bus, RS485 communication with the node controller; uplink and downlink communication and control part adopts modular design, on-site replacement, set free, easy to use (such as large number of sensors, or sensors distant from the primary controller, you can use the sensor input module connected to the CAN bus nearby). Functions and features? Uplink communication channels: GPRS or Ethernet? Downlink communication channels: CAN bus, RS485/RS232 communication with the node controller? Local upgrade: You can concentrator via a web interface for software upgrade? Buzzer alarm function? RS232 / RS485/USB Interface? 10/100M Ethernet interface four, the Central Monitoring Software Central Monitoring Software / PC management software SYS-SLCS V1.0 mainly on the entire lighting control system graphical monitoring, control and management, monitoring lighting status, functional configuration, while historical data, curves, reports, operational logs, energy statistics and other statistical functions. Features (1) using the Windows XP or Windows 7/8 operating system, Simplified Chinese graphical user interface; (2) using B / S architecture, via LAN / Internet environment monitoring and management anytime, anywhere; (3) through a central monitoring indoor server system for centralized monitoring and management; (4) with a total console, packet control, device settings, system settings, system logs, reports, statistics and other software modules; (5) has a running time and history functions, and need the flexibility to set; (6) with reporting capabilities, and can be flexibly set according to need; (7) strict rights management, ensuring system security; (8) independent database design, support for automatic backup; (9) can be achieved focus on the collection device parameters, combined with statistical analysis, scientific management. Technical parameters (basic system configuration requirements) 1 Windows XP Professional or Windows 7/8 Professional Edition (optional); 2 IIS 5.1 and above (optional); 3. NET Framework 2.0 or later (optional); 4 MySQL 5.1 and above or SQL Server 2000 and above (optional). |
Admin>>>
You are the 6416 visitor
Copyright © GuangDong ICP No. 10089450, Highland Technology Co., Ltd. of Shenzhen City Tour All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 6416 visitor
Copyright © GuangDong ICP No. 10089450, Highland Technology Co., Ltd. of Shenzhen City Tour All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility